Home >> Technical >>Technical Support >> Installation & Operaton of SiC Heating Elements
Details

Installation & Operaton of SiC Heating Elements


第3条 配图.jpg

n In order to keep furnace temperature and the load-bearing uniform of each element, before installation resistance distribution must be carried out. The 

resistance value deviation of each group should be below 10%


n As the element is very brittle, be careful while install and maintain to avoid any damage.

 

n When start to operate the furnace, raise voltage slowly and gradually, never give full load at one

 time, or the heating element will be damaged by over current impulse.

 

n To use the elements, you should prepare the adjustable transformer or silicon controlled trans-former, voltage meter, current meter and auto-control temperature meter etc. During the working, the voltage should be increased to maintain the 

furnace normal temperature because the resistance value will go up gradually caused by the oxidation 

of element. When the voltage get to the up limit of the transformer and the temperature is still low than

 the requirement, the furnace should be stopped, change the way of wire connection and then 

continue work.

 

n In the course of long operation of the furnace, if any individual heating element is damaged owing

 to certain reasons and should be changed, you should replace it with proper one whose resistance 

value corresponds to that of the old one, never use a new heating element random. If the heating 

element is much damaged or its resistance value increases too much and cannot reach the furnace 

temperature, it is better to replace all the heating elements with new ones. Test and mark the 

resistance value of the old elements having been replaced (with voltmeter and ammeter) and 

distribute them in low temperature area.

 

n Before the now furnace or the furnace that has not been used for a long time is used, they must 

be drying. When drying them, it is better to use old element or other source.

 

When firing apparatus or material, if there is water ejection, the furnace should have holes to eject water 

vapor or other waste gases in order to protect the elements service life.